Scaler Node
Inputs
  • in
Outputs
  • out
Version Introduced
2.2

The Signal Scaler Node is a very simple node that consumes an input signal through the input port in and scales the value by a factor (Scale Size, defaulting to 1) around a Scale Center (defaulting to 0.5).

Signal Scaler Nodes were introduced in firmware version 2.2.

Settings

The settings for this node control how the input value is scaled:

  • Scale Size: This is the amount that the input signal is scaled by.
  • Scale Center: This is the center around which the input signal scales. For instance, a center of 0 and scale of 2 will result in a '3' being scaled to a '6', while a center of 2 will result in a '3' being scaled only to a '4'